Naipu can supply you slurry pump impellers made of rubber or metal. The slurry pump’s impeller is an energy converter. It is the main rotating component of a slurry pump to impart and direct the centrifugal force to the slurry. The impeller vanes are the heart of the impeller. The rest of the impeller is to carry, protect and balance the impeller vanes during operation.

Overview

Slurry Pump Impeller type

The slurry pump impeller type can be open, semi-open, closed. Closed impellers have shrouds on both sides of the vanes, while open (or semi-open) impellers have only one shroud opposite the impeller entrance.

Advantages of the open impeller design:

  • 1. Possibility of machining the impeller surfaces which will increase efficiency of impellers;
  • 2. Blocking does not occur as easily as with the closed type;
  • 3. Wear on the bowl and impeller vane edge may be compensated by adjustment to bring clearance and thus efficiency back to normal.

Advantages of the closed impeller design:

  • 1. Axial thrust is reduced which may increase bearing life or allow a more economical shafting;
  • 2. Wear on the impeller vanes is not as critical for the adjustment of impeller/bowl clearance as with open impellers.

Semi-open impeller

Semi-open impellers are used to overcome the limitations of a closed design and depend on impeller diameter, size or structure of the solids, presence of entrained air, high viscosity, etc.

Naipu slurry pump impellers are more commonly of the closed type (with a front shroud), because of higher efficiencies and are less prone to wear in the front liner region.

The impeller design is crucial as it influences flow patterns and, ultimately, wear rates throughout the pump. Closed impellers are used for slurries with coarse particles for highest efficiency and best wear life–check maximum solids size. Open impellers are used for slurries with high viscosity, entrained air and when blockage problems can be foreseen.

Number of slurry pump impeller vanes

"More vanes give higher efficiency." This means that the more vanes there are, the higher efficiency will be, however, limitations exists as long wear life and the need to pass a required particle size have influence on the vane thickness.

The numbers of impeller vanes of Naipu slurry pumps usually vary between three and five depending on the size of the particles in the slurry.

NZJA-R Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
25NZJA-R 159 Open  3 20
40NZJA-R 184 Open  5 16
50NZJA-R 230 Closed  5 21
75NZJA-R 265 Closed  5 28
100NZJA-R 400 Closed  5 33
150NZJA-R 560 Closed  5 59
200NZJA-R 740 Closed  5 76
250NZJA-R 813 Closed  5 86
300NZJA-R 1027 Closed  5 104
350NZJA-R 1118 Closed  5 120
450NZJA-R 1440 Closed  5 130

NZJA-M Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
25NZJA-M 159 Open  5 14
40NZJA-M 184 Open  5 19
50NZJA-M 230 Closed  5 25
75NZJA-M 265 Closed  5 36
100NZJA-M 400 Closed  5 51
150NZJA-M 560 Closed  5 63
200NZJA-M 740 Closed  5 76
250NZJA-M 813 Closed  5 86
300NZJA-M 1027 Closed  5 90
350NZJA-M 1118 Closed  5 135
450NZJA-M 1440 Closed  5 130
550NZJA-M 1560 Closed  5 150
650NZJA-M 1800 Closed  5 210
750NZJA-M 2134 Closed  4 380

NZJL-R Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
200NZJL-R 572 Closed  5 85
250NZJL-R 571 Closed   5 83
300NZJL-R 665 Closed  5 57
350NZJL-R 750 Closed 5 65
400NZJL-R 840 Closed 5 85
450NZJL-R 950 Closed 5 97
550NZJL-R 1235 Closed 5 150
650NZJL-R 1425 Closed 5 120

NZJL-M Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
200NZJL-M 572 Closed  5 65
250NZJL-M 571 Closed   5 83
300NZJL-M 665 Closed  5 57
350NZJL-M 750 Closed 5 65
400NZJL-M 840 Closed 5 85
450NZJL-M 950 Closed 5 97
550NZJL-M 1235 Closed 5 150
650NZJL-M 1440 Closed 5 120

NZJF Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
50NZJF 225 Open  4 35
75NZJF 260 Open  4 38
100NZJF 390 Open  4 55
150NZJF 560 Open  4 63

NZJV-M Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
40NZJV-M 195 Open  5 12
65NZJV-M 290 Open  5 15
100NZJV-M 390 Open  5 32
150NZJV-M 480 Open  5 45
200NZJV-M 550 Open  5 65
250NZJV-M 605 Open  5 65
300NZJV-M 641 Open  5 65

NZJV-R Slurry Pump Impellers

Pump type Impeller specifications
  Max. diameter (mm) Type Blade No. Max. passed particle size (mm)
40NZJV-R 195 Open  5 12
65NZJV-R 290 Open  5 15
100NZJV-R 390 Open  5 32
150NZJV-R 480 Open  5 45

NZJH Slurry Pump Impellers

Pump type  Impeller specifications 
  Max. diameter  (mm)  Type  Blade No.  Max. passed particle size  (mm) 
25NZJH  330  Open   16 
50NZJH  457  Closed    31.8 
75NZJH  480  Closed    38 
100NZJH  711  Closed   57 
150NZJH  711  Closed   70 

    Case

  • Mongolia slurry pump

    Naipu slurry pump 550 used in CNGG Inner Mongolia Mining Co., Ltd

  • cyclone feed pump

    3 sets of Naipu cyclone feed pumps used in Yinchun Luming Mining plants.

  • 450 slurry pumps

    Naipu 450 slurry pumps were used in primary mill classifying plants in Tongguan Mining.

  • gold mine slurry pump

    Naipu supply 16 sets of 450 slurry pump for KSO and SABC circuit mill.

Consult Online

Consult Online

24-hour service online
Send Email

Email

[email protected]
Call Us

Call Us

86-21-67268186
Join us

Join Us

Realize our dreams together!

Follow Us

t f i y

Copyright © 2008 The Naipu Mining Machinery and New Materials Co., Ltd all rights reserved